Gfci Outlet Needed In Garage
This was covered by the same exception as the garage door opener outlet above.
Gfci outlet needed in garage. Gfci protection is required for 125 volt to 250 volt receptacles supplied by single phase branch circuits rated 150 volts or less to the ground. An electrician will charge an additional 50 to 100 dollars per hour to replace outlets. Up until the 2008 edition of the nec national electrical code there were two exceptions allowed for the gfci requirement at garage receptacles. A gfci outlet runs about 15 such as this levitron gfci outlet available from home depot.
But it wasn t always this way. Yes all 125 volt single phase 15 or 20 amp receptacles in a garage must be gfci protected with only one esoteric exclusion that we will cover later. Yes all garage outlets must be gfci protected no exceptions since 2008 gfci outlets have been required for all 125 volt single phase 15 and 20 amp outlets in the garage. 120volt 15amp garage circuits are typically wired with 14 2.
Do garage lights need to be gfci protected. The new 2020 nec national electrical code is out and kb electric llc is here to go over two of the changes for gfci protection every homeowner should know. Similarly outlets on your garage ceiling must be gfci compliant. Plus installing a gfci outlet reduces the risk of electric shock helping ensure the safety of you and your family.
This will protect your primary electrical system by using a dedicated circuit. But there was an exception for receptacles that are not readily accessible which is defined as above 6 8 above floor such as a ceiling garage door opener receptacle. The best solution is to have an electrician install a dedicated circuit with a standard outlet. In many homes necessary circuit breakers and gfcis are already installed but they can stop working unexpectedly so it is important to know how to replace gfci outlets when this happens.
1978 nec garage receptacles first required to be gfci protected. Hi randy the nec electrical code section 210 specifically article 210 52 g states that one receptacle outlet is required for each car space and nec article 210 8 a 2 states that gfci protection is required for all 120volt 15amp and 20 amp receptacles. All outlets in your garage must be gfci compliant regardless of where they are located. Nec 2020 code changes for gfci protection.
The nec 2020 code changes for gfci protection allow for the utmost safety for families and workers alike. Gfci receptacles are required in bathrooms garages crawl spaces basements laundry rooms and areas where a water source is present. What you should know.